screw air compressor problem (electrical side)

Guest May 1, 2015 1 Answer
Question
Getting problem of emergency stop in machine within few minute after start. All cable connection are ok. phase, fuses and connections are ok.

1 Answer

Expert 10 years ago
Hello, Does it give an error message like 'high temperature' or 'emergency stop'? If it is 'emergency stop', check the electrical connections on your emergency stop button, I have seen on several machines that because of vibrations the emergency stop gets activated. If that's not it.. Usually, if the machine stops after a few minutes, it is because of too high temperature. What is the element outlet temperature when the machine shuts down? There is a temperature sensor that measures the element outlet temperature. Sometimes this sensor gives faulty readings or jumps up and down for no reason, or because of a loose connection. Hope this helps! Good luck! Cas

Share Your Knowledge

Have experience with this issue? Help others by sharing your solution.