Bauer o13 diesel compressor not building pressure
Bauer O13 diesel compressor not building pressure
1 Answer
Hi,
Does it give any error message? There's an warning and an alarm LED. It will flash X times to indicate different problems.
Also please check the lights of the inputs and outputs on the small PLC - there are some sensors like temperature and oil pressure that open when something is wrong.
Please check and let me know.
And, this compressor as an unload mechanism using control air. At startup, there is no control air so it starts up unloaded - which is good.
There is a solenoid that should close a few seconds after start up. Then control pressure will built up and this will close the condensate drains in the intermediate stages.
Then, pressure should built up.
Hope this helps - let me know what you find and please report back with any new information :)
All the best,
Cas
Share Your Knowledge
Have experience with this issue? Help others by sharing your solution.