Mechanical Engineer
Dear Sir/madam
We have two GA15 FF compressors one working and the other standby. One of the compressors (Compressor 2) is running smoothly while the other has a problem that trips the motor. We have taken the following measurements on both compressors as detailed hereunder:
Atlas Copco rotary screw Compressor: GA15 FF 7.5CE 400 FM
Data
Compressor 1 (having problems)
Compressor 2
(working smoothly)
Remark
Relay setting
21 A
21 A
Measured phase current:
R
S
T
31.4
33.1
32.6
31.5
32.3
30.5
Temperature
Loading
Unloading
790c
(70-71) 0c
720c
670c
These remarks are valid only for compressor 1
§ Motor switches off after running for sometime
§ Oil finds its way into the air filter
§ Temperature of the oil air separation thank is very high
N.B: 1. These two compressors are installed side by side; one working and the other standby
- Both are getting power from the same line
- Both compressors have two independent breakers
- Compressor 1 run only for 5 hours when the problem started to transpire
Please advise on how we should go about resolving the problem?
Looking forward to your prompt action,
With kind regards,
Tadesse Woldeyes
Share Your Knowledge
Have experience with this issue? Help others by sharing your solution.