Fault emergency stop

Guest August 4, 2015 1 Answer
Question
why the sudden "emergency stop" (emergency button is not depressed) when the GA22 screw compressor was working normally (load-unload) with temperatures of 93-98 ° C, pressure 6,3-7,1bar and ambient temp. 30 ° C

1 Answer

Expert 10 years ago
Hello Henda, What is the exact message that get's displayed? Does this unit has the Elektronikon 1 or Elektronikon Mark 3 controller (with the F1/F2/F3 keys below the display)? This compressor has 4 safety stops: - Compressor element temperature - Defective pressure sensor - Motor overload - Emergency stop pressed If the compressor 'thinks' the emergency stop is pressed, while it wasn't, then probably there is a loose contact. Carefully wiggle all wires that go to the emergency stop. Do the same on the controller On the Elektronikon 1 controller it connects to connector 2X9 - pin 1. On the Elektronikon Mark 3 controller is connects to connector 2X9 - pin 3. Good luck and let me know how it goes. Cas