Atlas Copco GA22 will not load
7 Answers
Please, where does the control pressure come from? Assuming my compressor is off and i want to start it, where does the control pressure comes from.
As per the above air compressor problem of not loading, what you need to do is to check if your solenoid on the unloading valve gets enough power supply when the compressor is started for loading operation. There is supposed to be power supply to the solenoid when the compressor is started for loading operation to open the inlet valve for air to go in and when the compressor has reached its cut off pressure, then the power also cuts from the solenoid while the motor continue running.. You can also remove the solenoid and check by reading the coil and also testing it outside to confirm that it has good magnetism or weak magnetic force. If the solenoid is bad you will have the above problem of the compressor not loading.
Also, you will have same problem if the inlet valve spring is weak or bad as well as other kitting items like seals inside the unloading valve, so it will be advisable that you re-kit the unloading valve.
You should also be aware that if the minimum pressure valve (MPV) located on the top of the separator or air receiving tank is bad, may be due to weak or failed rings and seals, you could likely have similar problem and air returning back into the compressor., and it is advisable that when re-kitting the unloading valve, you also re-kit the mpv valve too.
You may remove the additional valve installed, because your unloading valve must open very well to allow the compressor to load at its rated capacity else you will be causing more damage to the unit and it will not serve your purpose.
Best Regards
Patrick Whowha
hello
I have opposite problem. Ga7ff. when I turn on compressor, state is unloading, solenoid is not activated but air pressure starts to build up. After a few seconds the state goes to loading, solenoid activates and no air coming out top of solenoid. Pressure builds up to 106psi then state goes to unloading, solenoid is deactivated and air comes out top of solenoid. But air pressure continues to build up until 135psi then safety valve blows.
I have checked everything. Replaced unloaded valve 3 times. Solenoid 3 times.
What could it be? I can't find any information about a problem like this if unloaded valve is not the issue?
Please help.
hello
to solve your problem replace new unloader kit, and also check whether your are placing the solenoid valve in proper position. fixing the solenoid valve in wrong direction results in loading even after auto unload.
reply if the above procedure works.
Why do we find oil inside the air filter and why my air outlet saneloid valve isnt energised at all
Share Your Knowledge
Have experience with this issue? Help others by sharing your solution.