This website requires Javascript for some parts to function propertly. Your experience may vary.

Page | Air Compressor Guide
info@air-compressor-guide.com Independent Troubleshooting & Training Resource
Q&A Archive Question

Alup Compressor air end blocked

haidara February 16, 2019 1 Answer
Question
dear sir, please note that we are having a problem in our compressor. the panel is giving us an error( 0912 d ) and it says (open circuit). can you please explain what the problem is. thank you

1 Answer

Expert 6 years ago

Hi,

I don't know this error and can't find anything about it.

But, it sounds like an electrical problem. Please check all connections on the main contactors - I suspect it's one of the feedback contacts that let's the control module know if the contactor is open or closed.

(there should be 3 big contactors: line, star and delta. Since star and delta contactors can -never- be energized at the same time, there are auxiliary contacts on each contactor that prevent this, either directly, or by feedback to the main control unit).

Hope this helps,

Cas

Share Your Knowledge

Have experience with this issue? Help others by sharing your solution.