This website requires Javascript for some parts to function propertly. Your experience may vary.

Page | Air Compressor Guide
info@air-compressor-guide.com Independent Troubleshooting & Training Resource
Q&A Archive Question

altas copco compressor GA 132 oil problem.

Guest June 2, 2014 2 Answers
Question
Dear, We have the problem of GA132. The separator D.p (pressure difference) is 0.45 but oil is drain in drain line. Oil quantity in compressed air is very high. So please talk to me what is the reason of this.

2 Answers

Expert 11 years ago
Hello Ankur, Thanks for your question. There could be many causes for your problem, but these are the most common ones: - The compressor is running too hot. What is the discharge (element outlet) temperature? When the compressor runs too hot, the oil becomes very thin and will be able to pass through the separator. - When was the last time the separator was changed? 0.45 bar is still good value, but if it has been a long time since the last change, it's better to change it. - How is the oil level? If the oil level is too high, you will also get oil carry-over to your compressed air system. - The scavenge line could be blocked or not installed correctly. The scavenge line sucks up all the oil that collects on the bottom of the oil separator. If the scavenge line is blocked, the oil level on the 'dry side' of the separator will rise and will leave the compressor with the compressed air. Best is to open up the separator vessel and check the scavenge line and the condition of the oil separator (or change it, while you're at it). Good luck and let me know if this fixed it or if you need any more info. Cas.
Expert 11 years ago
Hello Ankur, Thanks for your question. There could be many causes for your problem, but these are the most common ones: - The compressor is running too hot. What is the discharge (element outlet) temperature? When the compressor runs too hot, the oil becomes very thin and will be able to pass through the separator. - When was the last time the separator was changed? 0.45 bar is still good value, but if it has been a long time since the last change, it's better to change it. - How is the oil level? If the oil level is too high, you will also get oil carry-over to your compressed air system. - The scavenge line could be blocked or not installed correctly. The scavenge line sucks up all the oil that collects on the bottom of the oil separator. If the scavenge line is blocked, the oil level on the 'dry side' of the separator will rise and will leave the compressor with the compressed air. Best is to open up the separator vessel and check the scavenge line and the condition of the oil separator (or change it, while you're at it). Good luck and let me know if this fixed it or if you need any more info. Cas.

Share Your Knowledge

Have experience with this issue? Help others by sharing your solution.