air comp continue loading?.i am replaced intake&,solenoid valve& pressure switch

Guest July 25, 2015 1 Answer
Question
air comp continue loading?.i am replaced intake&,solenoid valve & pressure switch

1 Answer

Expert 10 years ago
Hi Krishna, Please check if there is power going to the solenoid. Do you hear it CLICK when you switch from load to unload? If no, check all electrical connections. If yes, then all this is OK and the problem is with the inlet valve itself. Often it simply gets stuck in open or closed position. Depending on the design, it could also be that some seals are leaking which prevents (control) pressure from building up to close the valve. Good luck! And be careful when opening the inlet valve, they often contain very powerful springs! Cas