Overheating / High Cylinder Temperature – Industrial Reciprocating Air Compressor Troubleshooting

Compressor running hot or cylinder head too hot to touch—usually caused by valve problems, ventilation issues, or excessive duty cycle.

Industrial systems
Field-tested diagnostics
Independent & unbiased

Safety Notice

Hot surfaces can cause burns. Allow the compressor to cool before touching the cylinder head or performing service. Some compressors have high-temperature safety switches—don't bypass them.

What this problem usually means

Reciprocating compressors generate heat during compression—that's normal. But excessive heat, where the cylinder head becomes too hot to touch or triggers a thermal shutdown, indicates a problem.

High temperatures accelerate wear, break down oil, and can damage valves and gaskets. Most overheating issues stem from poor ventilation, valve problems, or running the compressor beyond its duty cycle.

Check these first

5–10 minute checks before diving deeper

  • Check ambient temperature—is the compressor in a hot environment?
  • Is there adequate ventilation around the compressor?
  • Check the cooling fins on cylinder—are they clogged with dust/debris?
  • Listen for valve problems—chattering or hissing from cylinder head
  • Check the head gasket area for leaks (hissing sound)
  • Is the belt slipping? (causes motor to work harder)
  • What's the duty cycle? Is the compressor running continuously?
  • Is the pressure setpoint too high for the compressor rating?

Common root causes

Why this happens in industrial reciprocating compressors

Poor ventilation

Compressor in enclosed space, too close to wall, or in direct sunlight. Heat can't dissipate. Improve airflow around the unit.

Leaking or broken valves

Damaged inlet or outlet valves cause recompression of air, generating excessive heat. Inspect and replace valve plates.

Blown head gasket

Gasket failure causes air leak and makes the compressor work harder for less output. Listen for hissing at the head-to-cylinder joint.

Dirty cooling fins

Dust and debris on cylinder fins reduce heat dissipation. Clean fins with compressed air or brush.

Excessive duty cycle

Running beyond rated duty cycle (e.g., 100% on a 50% duty-rated unit). Compressor needs rest time to cool. May need larger unit.

What NOT to do

Don't aim a fan at the compressor as a permanent solution—this masks the root cause. Find and fix the underlying issue (ventilation, valves, duty cycle).